TBEXEC and library conversion messages

Error and audit messages generated by the batch utility program TBEXEC, and other programs are identified and described in alphabetical order in the following table.

Messages issued from tableBASE in conjunction with the TBEXEC and other programs/utilities vary from function to function, and are listed in the tables below. The error code is shown at the end of the message, while the originating program can be identified by the message prefix. The following prefixes may be encountered:

IOSRT-51—indicates TBEXEC in conjunction with subroutine DK1T0051
T1182—indicates utility DK1TCNV in conjunction with subroutine DK1T0051

Table 104. Messages and error codes for TBEXEC: DK1T0051

Msg Code

Meaning / Instructions

IOSRT-51 <message> ERROR 22

DDNAME provided in command is not a valid DDNAME or it is not allocated in the jobstream.

IOSRT-51 <message> ERROR 26

CANNOT OPEN EXCLIST: <filename> cannot be found. Please correct the filename and rerun.

IOSRT-51 <message> ERROR 27

The dataset for the DDname specified must be a DISK file; it is not.

IOSRT-51 <message> ERROR 30

The DSORG (dataset organization) for the DDNAME specified must be compatible for the usage: VSAM RRDS, BDAM or QSAM for a library, QSAM or a member of a PDS(E), SYSIN or SYSOUT for a sequential dataset.

IOSRT-51 <message> ERROR 31

The RECFM (Record Format) for the DDNAME specified must be F for a library, F or FB for sequential input. FA and FBA are allowed for sequential output of Report files.

IOSRT-51 <message> ERROR 32

The BLKSIZE (Block Size) parameter for the DDNAME specified must be a multiple of record length.

IOSRT-51 <message> ERROR 33

The output dataset for this DDname may not be allocated DISP=SHR.

IOSRT-51 <message> ERROR 34

An error was encountered processing a VSAM dataset. See the JESMSGLG for a description of the VSAM error.

Note:
The message handling is used by many processes. Depending upon how the message is generated, it may contain only the IOSRT error message number and the associated message text (shown as <message> above), or just the message number.
Table 105. Messages and error codes for library conversion

Msg Code

Meaning / Instructions

T1182: <message> ERROR Invalid DDname

DDNAME provided in command is not a valid DDNAME or it is not allocated in the jobstream.

T1182: <message> ERROR Not a disk file

The dataset for the DDname specified must be a DISK file; it is not.

T1182: <message> ERROR Non zero parameters

The DSORG (dataset organization) for the DDNAME specified must be compatible for the usage: VSAM RRDS, BDAM or QSAM for a library, QSAM or a member of a PDS(E), SYSIN or SYSOUT for a sequential dataset.

T1182: <message> ERROR RECFM

The RECFM (Record Format) for the DDNAME specified must be F for a library, F or FB for sequential input. FA and FBA are allowed for sequential output of Report files.

T1182: <message> ERROR BLKSIZE

The BLKSIZE (Block Size) parameter for the DDNAME specified must be a multiple of record length.

T1182: <message> ERROR SHR WRITE

The output dataset for this DDname may not be allocated DISP=SHR.

T1182: <message> ERROR VSAM

An error was encountered processing a VSAM dataset. See the JESMSGLG for a description of the VSAM error.

T1182: <message> INVALID BLKSIZE

The specified blocksize for the target library was invalid. tableBASE library blocksizes must be 3120.

Note:
Certain structural errors for paged tables in Version 5 tableBASE libraries may cause the Library conversion process to fail with abend S209. This same error can occur when running DK1TLCHK.