Messages issued from the tableBASE components, such as the VTS Agent, CICS, Batch and others, vary from function to function, and are listed in the table below. These messages can usually be viewed on the JESMSGLG. Any Severe Errors (S) messages should be referred to tableBASE Customer Support. Messages are in the format DK1nnnnnA where DK1 is the prefix, followed by a five digit numeric code and an error code letter. The error code letter indicates the type and severity of the error message:
- E—Error (usually indicates user error)
- I—Information
- W—Warning
- A—Action (user action is required)
- S—Severe (no further processing is possible)
Msg Code |
Text |
Meaning / Instructions |
---|---|---|
DK100049S |
NO CMDAREA IN CALL TO TBLBASE. ABENDING. |
There was no command area supplied. Ensure that a command area is supplied for the tableBASE call. |
DK100100W |
Unexpected non-zero return code from user exit |
|
DK100107W |
A message was truncated at 207 characters |
Information only. |
DK100200S |
Initialization failed |
|
DK100200S |
tableBASE Initialization failed |
|
DK100201S |
tableBASE PC Server unavailable |
The tableBASE PC Server is not running. It must be running in order for tableBASE to initialize in batch jobs, CICS regions, IMS regions, DB2 SPAs and VTS-TSRs. |
DK100202I |
tableBASE V<nnn> is initializing for <customername> |
Information only. |
DK100203I |
tableBASE <interface> license expires on <yyyy/mm/dd> |
Information only. |
DK100204I |
Executing in Step=<stepname> |
Information only. |
DK100205I |
Executing in JOB Step=<stepname> PROC Step=<stepname> |
Information only. |
DK100206S |
tableBASE PC Server does not support LOAD |
Ensure the latest PC Server is running. |
DK100207E |
DK1TX071 not loaded; System Exits disabled |
Contact DataKinetics Technical Support for assistance. |
DK100207E |
DK1TX072 not loaded; User Exits disabled |
Contact DataKinetics Technical Support for assistance. |
DK100208S |
Unable to locate tableBASE GCA |
Ensure the latest PC Server is running. |
DK100209S |
tableBASE PC Server unavailable |
Ensure the latest PC Server is running. |
DK100210E |
Module DK1TNUCL not loaded |
Contact DataKinetics Technical Support for assistance. |
DK100210I |
Unable to locate tableBASE GCA |
Information only. |
DK100211I |
Unable to locate tableBASE GCA. |
Information only. |
DK100213E |
Error in tableBASE PC server |
Contact DataKinetics Technical Support for assistance. |
DK100214E |
Create CMA Named Token failed |
Contact DataKinetics Technical Support for assistance. |
DK100214E |
CMA GETMAIN failed |
Contact DataKinetics Technical Support for assistance. |
DK100216S |
$DOPC GRANDE Failed |
Ensure the latest PC Server is running. |
DK100217S |
$DOPC Failed to Load DK1TROTB. |
Check that DK1TROTB is available for an MVS LOAD. |
DK100218S |
$DOPC Free LX Index Failed |
Contact DataKinetics Technical Support for assistance. |
DK100221E |
I/O ERROR:<text> |
Contact DataKinetics Technical Support for assistance. |
DK100222E |
QSAM ERROR: FUNCTION=<xxxxxxxx>,FILE=<ffffffff> |
Contact DataKinetics Technical Support for assistance. |
DK100224E |
I/O PROBLEM: FILE=<xxxxxxxx> FUNC=<ffffffff> RESP=<dddd> RESP2=<dddd> |
Contact DataKinetics Technical Support for assistance. |
DK100225W |
JOB:<jobname>,ID:<userid>,TSR:<TSRname>, CMD:<cc>,TBL:<tablename>, – WAITING <nnnnnn> SECS FOR MAPLOCK HELD BY <jobname2> <task-id> |
TSR space allocation is blocked by another process accessing this TSR. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock. CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends. If the problem persists and is happening in a VTS-TSR, contact DataKinetics Technical Support for instructions on how to alleviate the problem.
|
DK100226W |
Please change DD TBOPTV to TBOPT |
Information only. |
DK100226i |
Please change DD TBOPTV to TBOPT |
Information only. |
DK100227W |
JOB:<jobname>,ID:<userid>, TSR:<TSRname>, CMD:<cc>, TBL:<tablename>, – WAITING <nnnnnn> SECS FOR GLOBAL TCELOCK HELD BY <jobname2> <task-id> |
Access to the TSR table list is blocked by another process. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.
CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends. If the problem persists and is happening in a VTS-TSR, contact DataKinetics Technical Support for instructions on how to alleviate the problem.
|
DK100227W |
JOB:<jobname>,ID:<userid>,TSR:<TSRname>, CMD:<cc>,TBL:<tablename>, – WAITING <nnnnnn> SECS FOR TCELOCK HELD BY<jobname2> <task-id> |
Access to the table in the TSR is blocked by another process using the table. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.
CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends. If the problem persists and is happening in a VTS-TSR, contact DataKinetics Technical Support for instructions on how to alleviate the problem.
|
DK100228W |
JOB <jobname> IN <VTSname> WAITING <nnnnnnnn> SECONDS TABLE ENQ <tablename> |
Job is waiting for VTS-TSR table enqueue–not received yet. |
DK100229W |
JOB:<jobname>,ID:<userid>,TSR:<TSRname>, CMD:<cc>,TBL:<tablename>, – WAITING <nnnnnn> SECS FOR TLBLOCK HELD BY <jobname2> <task-id> – LIB DD:<DDname>,DSN:<DSNname> |
Access to the tableBASE library is blocked by another process in the same region using the library. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.
CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends.
|
DK100230I |
TBOPT Processing |
Information only. |
DK100231I |
<keyword>=<value> |
Information only. |
DK100232E |
Invalid value |
The value entered is invalid. |
DK100233E |
Missing keyword |
A keyword is missing. |
DK100234E |
Invalid keyword |
The keyword entered is invalid. |
DK100235E |
Value exceeds maximum allowed |
The value provided exceeds the maximum allowed value. |
DK100236E |
Keyword not allowed in this environment |
The parameter provided is not allowed for this interface. |
DK100237E |
Missing ”=” |
A “=” is missing in the parameter. |
DK100238E |
Invalid quoted string |
The string is invalid. |
DK100239E |
Value field too wide |
The value entered is too large. Correct and try again. |
DK100240E |
Value less than minimum allowed |
The value entered is smaller than the minimum required. |
DK100241E |
Missing value |
There is a missing value in the parameter. |
DK100242E |
Keyword (or alias) previously specified |
The keyword has already been specified by using another alias name. |
DK100243E |
Option supported only in TBOPTGEN |
This parameter must be entered in the distributed source for DK1V1134 or DK1Txx34 and rebuilt. It cannot be entered in the input for the TBOPT DD card. |
DK100244I |
MAXNMTAB set to <nnnnnn> |
Information only. |
DK100245W |
VTSONLY not valid with LIB entries |
|
DK100246W |
Invalid VTS prefix for LIB<nn>=<xxxxxxxx> |
|
DK100247W |
Empty value: LIB<xx> – LIB<yy> |
|
DK100248W |
LIB<xx> exceeds max allowed <mm> |
|
DK100249W |
MULTOPNX=N is not valid |
|
DK100250I |
TBOPT Parameters: (*= Parameters not taken from TBOPT input file) |
Information only. |
DK100251I |
<keyword>=<value>. |
Information only. |
DK100252I |
<<<<<<< TBOPT Done >>>>>> |
Information only. |
DK100253I |
<message> |
Information only. |
DK100255E |
HASH_LOW_DEN_LIM must be <= 2/3 HASH_HI_DEN_LIM |
Reset the density limits. |
DK100256I |
TSRSIZE set to LDS size of <nnnnnnn>K |
Information only. |
DK100258I |
MAXNMTAB set by preformatted LDS TSR |
Information only. |
DK100260I |
DK1TX066 Exit Manager Initializing |
Information only. |
DK100262W |
Exit <xxxxxxxx> not loaded and disabled |
|
DK100263I |
Exit <xxxxxxxx> is loaded and enabled |
Information only. |
DK100264I |
DK1TX066 Exit Manager Shutdown complete |
|
DK100265W |
Exit name <xxxxxxxxxxxxxxxx> not found in current release |
|
DK100266E |
PC Service unavailable; required for VTS_TSR use |
Ensure that the correct version of the tableBASE PC Server is running. |
DK100270E |
Insufficient storage to process strobe data; strobe suppressed. |
The strobe data file has run out of space so tableBASE strobe data will be suppressed. |
DK100271E |
Error on CICS WRITE JOURNALNUM; Strobe logging suppressed |
|
DK100272E |
WRITE JOURNALNUM RESP=<1234>, RESP2=<1234> |
|
DK100273E |
Dynalloc of strobe report failed. Strobe suppressed. |
|
DK100274I |
STROBE=0 forced for DB2 Stored Procedure |
Information only. |
DK100275E |
Module DK1TRSTA not found. |
Contact DataKinetics Technical Support for assistance. |
DK100280E |
QSAM ERROR: FUNCTION=<xxxxxxxx>,FILE=<ffffffff> |
Contact DataKinetics Technical Support for assistance. |
DK100281E |
STROBE OUTPUT SUPPRESSED |
tableBASE strobe report output (for file TBTSRPT) has been suppressed due to some error in the file, possibly a file overflow. Try increasing the disk space for the strobe report output file, TBTSRPT. |
DK100282E |
I/O ERROR: |
Contact DataKinetics Technical Support for assistance. |
DK100283E |
TBTSRPT spin failed. See JESlog for messages. |
|
DK100284E |
TBTSRPT test failed. See JESlog for messages. |
|
DK100286E |
SYSPRINT DD MISSING. Run terminated. |
A SYSPRINT DD card is required in the job. |
DK100292W |
DEBUG TRACE requested but not started |
Contact DataKinetics Technical Support for assistance. |
DK100292E |
DEBUG TRACE requested but not started |
Contact DataKinetics Technical Support for assistance. |
DK100293S |
tableBASE must be initialized on QR TCB. Use tran TBDR TBINIT or PLTPI. |
|
DK100295A |
Specify character for PC server Named Token |
|
DK100300S |
SYSTEM FAILURE: <xxxxxxxx> Code=<cccc>/<hhhhhhhh>, Reason=<rrrr>/<hhhhhhhh> |
Contact DataKinetics Technical Support for assistance. |
DK100300S |
Call from <xxxxxxxx> Offset <xxxx> |
Contact DataKinetics Technical Support for assistance. |
DK100300S |
R0-R7 <xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx ….>. |
Contact DataKinetics Technical Support for assistance. |
DK100300S |
R8-R15 <xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx ….> |
Contact DataKinetics Technical Support for assistance. |
DK100301S |
Logic error; Dumpid <xxx> taken to TBDUMP. |
Contact DataKinetics Technical Support for assistance. |
DK100301S |
Logic error dump taken. Dumpcode is LGIC. Dumpid is <nnnnnnnn>. |
Contact DataKinetics Technical Support for assistance. |
DK100302S |
System ENQ limit exceeded. Task abended. |
Contact DataKinetics Technical Support for assistance. |
DK100303I |
CLOS-VTS <VTSname> Failed. Return Code = <nnnn> |
tableBASE internal processing to end its access to a VTS-TSR failed because the VTS-TSR was canceled before the task terminated. This message is informational only. |
DK100310W |
tableBASE TSR <nnn>% Allocated. TSR is local TSR. Owned by Job <jobname> |
The series of space management algorithms used in prior levels of V6 was changed in level 8. It now only issues a message when the TSR usage rises above a threshold and does not indicate what algorithm is being used. Setting the TSR_WARNING_FREQ = 0 will cause all the messages to be displayed once the TSR space usage threshold is crossed from below the threshold to above it or exactly equal to it. The default FREQ setting is 1 (i.e. only display one message per second, at the most). Level 8 will issue this message anytime the TSR usage rises above the value in TSR_WARNING_PCT. (The Default TSR_WARNING_PCT is 85.) Level 8 warnings start when the usage is exactly the TSR_WARNING_PCT value or higher. For more details refer to the TBOPT parameter settings in the tableBASE Installation Guide. |
DK100311W |
tableBASE TSR <nnn>% Allocated. VTS-TSR name is <vtsname>. Owned by Job <jobname>. |
Same as for message DK100310W, but applies to VTS-TSR. |
DK100330I |
DDNAME <ddname> is not a tableBASE Release 6 format library. |
Information only. |
DK100331W |
LIBRARY FREE SPACE MAP INCONSISTENT WITH LEFT BLOCK COUNT |
|
DK100332I |
Caching requested for DDname <ddname>. Caching not permitted on this library. Processing with no cache. |
|
DK100340W |
Old form ML mixed with use of extended ML |
|
DK100362E |
ABEND DURING UPDATE PROCESS RC=95 SC=<xx> |
|
DK100400E |
tableBASE User Error Abend <xxxx>, Reason=<dddd/hhhh> |
For more information, call DataKinetics Technical Support. |
DK100400E |
tableBASE User Error Abend <xxxx>, Command=<xx>,<tablename> |
For more information, call DataKinetics Technical Support. |
DK100400E |
tableBASE User Error Abend <xxxx>, TBLBASE Initializing |
For more information, call DataKinetics Technical Support. |
DK100400E |
tableBASE User Error Abend <xxxx>, Reason=<dddd/hhhh>, Command=<xx>,<tablename> |
For more information, call DataKinetics Technical Support. |
DK100400E |
tableBASE User Error Abend <xxxx>, Reason=<dddd/hhhh>, TBLBASE Initializing |
Abend code G200 indicates a CICS environment; 0200 indicates otherwise. For more information, call DataKinetics Technical Support. |
DK100411E |
TSR Create failed: Failed by site IEFUSI |
Contact DataKinetics Technical Support for assistance. |
DK100412E |
TSR Create failed: MVS resource shortage |
Contact DataKinetics Technical Support for assistance. |
DK100413W |
SNAP SUPPRESSED; GETMEM SHORTAGE |
Contact DataKinetics Technical Support for assistance. |
DK100414E |
TSR Create failed: LDS Smaller than TSR SIZE |
|
DK100415E |
TSRACCESS=RO using empty LDS |
|
DK100416I |
TSR successfully mapped to LDS |
Information only. |
DK100417I |
TSR successfully saved on LDS |
Information only. |
DK100471E |
BDAM ERROR: File=<ffffffff>, Function=<xxxxxxxx> |
Contact DataKinetics Technical Support for assistance. |
DK100472E |
VSAM ERROR: File=<ffffffff>, Function=<xxxxxxxx>, Reg15=<rrrrr>, Error Code=<xxxxx> |
Contact DataKinetics Technical Support for assistance. |
DK100472E |
I/O ERROR: <text> |
Contact DataKinetics Technical Support for assistance. |
DK100472E |
<xxxx> ERROR: File=<ffffffff>, Function=<xxxxxxxx>, Resp=<rrrrr>, Resp2=<pppppp> (Resp2=VSAM Response) |
Contact DataKinetics Technical Support for assistance. |
DK100473E |
VSAM ERROR: File=<ffffffff>, Request=ATTR2, Retcode=<xxx>, Reason=<yyy>, R15=<zzz> DSNAME=<dsname> |
Contact DataKinetics Technical Support for assistance. |
DK100476E |
xxAM ERROR: FUNCTION=<xxxxxxxx>,FILE=<ffffffff> |
Contact DataKinetics Technical Support for assistance. |
DK100477E |
I/O ERROR: <text> |
Contact DataKinetics Technical Support for assistance. |
DK100477E |
VSAM ERROR: FUNCTION=<xxxxxxxx>,REG15=<rrrrr>,ERROR CODE=<xxxxx>,FILE=<ffffffff> |
Contact DataKinetics Technical Support for assistance. |
DK100490E |
ERROR ON TBDEBUG FILE, REASON=<xxxx>, DEBUG DISABLED |
Contact DataKinetics Technical Support for assistance. |
DK100494E |
Persistent Task ended before end of step |
Contact DataKinetics Technical Support for assistance. |
DK100495I |
IN ROTBVTSD |
Information only. |
DK100496E |
Multitasking requires TBOPT Multitasking=Y be set |
Reset MULTITASKING parameter in TBOPT |
DK100497E |
failed to delete ESTAE |
Contact DataKinetics Technical Support for assistance. |
DK100501S |
EXEC CICS FAILURE: <xxxxxxxx> Resp=<cccc/hhhhhhhh>, Resp2=<cccc/hhhhhhhh> |
Contact DataKinetics Technical Support for assistance. |
DK100511E |
TSR Create failed: Failed by site IEFUSI |
Contact DataKinetics Technical Support for assistance. |
DK100512E |
TSR Create failed: MVS resource shortage |
Contact DataKinetics Technical Support for assistance. |
DK100513W |
SNAP suppressed; GETMEM shortage |
Contact DataKinetics Technical Support for assistance. |
DK100530I |
No storage for QTCWA; QCT function not used. |
Information only. |
DK100531I |
Module DK1TRSTA not found; QCT function not used. |
Information only. |
DK100532I |
Attaching QCT x |
Information only. |
DK100533I |
QCT X Detached |
Information only. |
DK100550I |
tableBASE <version> – Resource manager initializing |
Information only. |
DK100551I |
tableBASE Resource manager initialized |
Information only. |
DK100552E |
tableBASE Initialization Error |
Contact DataKinetics Technical Support for assistance. |
DK100553I |
tableBASE Initialization Failed |
Information only. |
DK100554I |
tableBASE Starting tblBASE |
Information only. |
DK100555I |
tableBASE tblBASE started |
Information only. |
DK100556I |
tableBASE Deactivating |
Information only. |
DK100557I |
tableBASE Deactivated |
Information only. |
DK100558E |
tableBASE Deactivation Error |
Contact DataKinetics Technical Support for assistance. |
DK100559I |
tableBASE Deactivation Failed |
Information only. |
DK100560I |
tableBASE Restarting |
Information only. |
DK100561I |
tableBASE Verifying |
Information only. |
DK100562I |
tableBASE Verify completed |
Information only. |
DK100563I |
tableBASE – Error Info: Func(<functionname>/<subfunctionname>) Resp(<responsecode>) Resp2(<responsecode>) |
This is error information received by tableBASE when requesting a CICS service function. Refer to the CICS manuals as required. |
DK100564I |
DK1TCIN used in PLT takes one of TBINIT (default) or INIT. |
Information only. |
DK100565I |
Successful <xxxx> INIT must be done before <xxxx> TBCALL |
Information only. |
DK100566I |
Verification failure |
Information only. |
DK100567E |
The tableBASE PC Server must be running for tableBASE to initialize. |
The tableBASE PC Server is not running. It must be running in order for tableBASE to initialize in CICS regions. |
DK100568E |
Program DK1TCIN must be defined as CONCURRENCY(QUASIRENT) |
Define DK1TCIN as per message and try again. |
DK100569E |
Module DK1CBASE must be current to determine version. |
Contact DataKinetics Technical Support for assistance. |
DK100570I |
<xxxx> takes TBINIT or TERM as a parameter |
Information only. |
DK100571I |
Phase in of <xxxxxxxx> not allowed by CICS; current in-storage copy used. |
Information only. |
DK100572I |
<xxxxxxxx> LP=<xxxxxxxx> EP=<xxxxxxxx> AM=<xx> RC=<xxxxxxxx> UC=<xxxxxxxx> |
Information only. |
DK100573I |
Module <xxxxxxxx> not loaded |
Information only. |
DK100574I |
Module <xxxxxxxx> not found. |
Information only. |
DK100575I |
EX=<xxxxxxxx> EN=<xxxxxxxx> STST=<xxxx> SHST=<xxxx> TAST=<xxxx> TALN=<xxxxx> GALN=<xxxxx> |
Information only. |
DK100576I |
<xxxxxxxxxxxxxxxx/xxxxxxxx> OK |
Information only. |
DK100577I |
<xxxxxxxx> LP=<xxxxxxxx> EP=<xxxxxxxx> LEN=<xxxxxxxx> AM=<xxx> KEY=<x> |
Information only. |
DK100578I |
tableBASE – Shutdown Completed. |
Information only. |
DK100579I |
tableBASE – Shutdown Aborted: Internal Resource Anchor Block (RCABLK) not found. |
Information only. Contact DataKinetics Technical Support for further information about this message. |
DK100580I |
tableBASE – Shutdown Aborted: TRUE TBASECRM not enabled. |
Information only. Contact DataKinetics Technical Support for further information about this message. |
DK100590E |
TBL BASE ERROR DEBUG WTD, REASON=<xxxx>, DEBUG DISABLED |
Contact DataKinetics Technical Support for assistance. |
DK100595I |
Trans error dump taken. Dumpcode is DKL1. Dumpid is <xxxxxxxx> |
Information only. |
DK100596E |
CICS Assign failed (Resp/Resp2=<nnnnn/nnnnn>); dump suppressed |
Contact DataKinetics Technical Support for assistance. |
DK100597E |
CICS DUMP TRANSACTION failed (Resp/Resp2=<nnnnn/nnnnn>). Dump for userid <xxxxxxxx> not taken. |
Contact DataKinetics Technical Support for assistance. |
DK100600I |
tableBASE V<vrm> VTS <xxxxxxxx> initialized |
Information only. |
DK100601E |
GCA cannot be located; VTS stopping |
The tableBASE PC Server is not running. It must be running before any VTS-TSRs can be brought up. |
DK100602E |
VTS Agent incompatible with GCA structure |
Contact DataKinetics Technical Support for assistance. |
DK100603E |
Duplicate VTS attempting to start; auto-stopping |
Another VTS with the same name is already running. |
DK100604E |
Program <xxxxxxxx> is not APF authorized |
The program must be APF authorized to run this task. |
DK100605E |
V<vrm> Environment not ready; VTS stopping |
Neither the tableBASE PC Server nor compat VTS Group Manager are running. Either one must be running before any VTS-TSRs can be brought up. |
DK100606E |
Incompatible DK1VBASE; VTS stopping |
The version of DK1VBASE is not compatible with this release. |
DK100608E |
Not authorized to start VTS resource: <vtsresourcename> |
This userid is not authorized to start the VTS resource named due to lack of RACF authorization. A minimum of CONTROL access is required to start a RACF-protected VTS. |
DK100610E |
Error in <xxxxxxxx> macro; RC/REASON=<xxx/yyyy> |
Contact DataKinetics Technical Support for assistance. |
DK100620E |
VTS is running in a Non-level 8 GCA |
Contact DataKinetics Technical Support for assistance. |
DK100629E |
Invalid non-level 8 GCA |
Contact DataKinetics Technical Support for assistance. |
DK100630I |
Console interface is available |
Information only. |
DK100631E |
Invalid command; command ignored |
The command supplied is invalid. |
DK100632W |
‘REFRESH not supported in tableBASE <vv> VTS |
The RF command is not supported in VTS. |
DK100633I |
SHUTDOWN |
Information only. |
DK100634I |
STOP command received, V<vrm> VTS <xxxxxxxx> terminating |
Information only. |
DK100636W |
switching TSRACCESS to RW, VTS <xxxxxxxx>: <nnnn> users may be affected |
Warning message. |
DK100637W |
TSRACCESS=RW forced RO for locking-<xxxxxxxx> |
Warning that the TSR access mode has been force switched to RO. |
DK100638W |
switching TSRACCESS to RO, VTS <xxxxxxxx>: <nnnn> users may be affected |
Warning message. |
DK100639E |
Not authorized to stop VTS resource: <vtsresourcename> |
This userid is not authorized to stop the VTS resource named due to lack of RACF authorization. A minimum of CONTROL access is required to stop a RACF-protected VTS. |
DK100701S |
tableBASE PC Server unavailable, required for license options |
The tableBASE PC Server must be running. |
DK100702I |
TSR size reset to LDS size |
Applicable only for VTS Manager. |
DK100703S |
Invalid LDSTSR dataset |
Applicable only for VTS Manager. |
DK100704W |
TSRACCESS forced to RO: LDSTSR DISP=SHR |
Due to the disposition of the LDS dataset, the TSR access mode is forced to RO. Applicable only for VTS Manager. |
DK100705I |
MAXNMTAB ignored for TSRACCESS=RO |
Applicable only for VTS Manager. |
DK100706W |
SYSPLEX=Y incompatible with TSRACCESS=RW; TSRACCESS set to RO |
Applicable only for VTS Manager. |
DK100707E |
TPVM incompatible with COMPAT VTS Agent |
Applicable only for VTS Manager. |
DK100708I |
StrobeMethod 3 allowed only for VTS |
Information only. |
DK100709E |
StrobeMethod 3 required for VTS with non-zero TSR_KEY-PROTECT |
When a VTS is hardware key-protected, TBOPT option STROBEMETHOD=3 must be used. |
DK100710W |
TSRACCESS forced to RO: TSR_KEY_PROTECT set |
Warning message. A hardware key-protected VTS can only be started up in read-only mode. |
DK100800I |
tableBASE PC server V<vrm> available |
The tableBASE PC Server is now running. It must be running in order for tableBASE to initialize in batch jobs, CICS regions, IMS regions, DB2 SPAs and VTS-TSRs. |
DK100802E |
PC server <xxxxxxxx> terminating; see message DK100803I for reason. |
Contact DataKinetics Technical Support for assistance. |
DK100803I |
<variable length message text> |
Information only. |
DK100804S |
System must support 64-bit architecture |
Starting with Version 7, tableBASE requires z/OS running on 64-bit hardware which supports the General Instructions Extension Facility (GIEF), the Long Displacement Facility, the Extended-immediate Facility and the Execute-extensions Facility. These are provided with the Z10-EC processor or higher. |
DK100805W |
License checking error <nnn> for <pppppppp> |
The license checker encountered an error. Contact DataKinetics Technical Support for assistance. |
DK100806W |
Error <nnn>-<rrr> LOADing DK1TLICK; <pppppppp> not licensed |
Error loading the license checker. Contact DataKinetics Technical Support for assistance. |
DK100807W |
Error <nnn> ATTACHing DK1TLICK for <pppppppp> |
Error attaching the license checker. Contact DataKinetics Technical Support for assistance. |
DK100811I |
Invalid command; ignored: <cccccccc> |
Information only. |
DK100812I |
STOP command received |
Information only. |
DK100820W |
DK1TPC01/DK1TLICK interface mismatch <nnn/nnn> |
Contact DataKinetics Technical Support for assistance. |
DK100821W |
PC Server <vvvv> does not support <pppppppp> |
Contact DataKinetics Technical Support for assistance. |
DK100822W |
<pppppppp> not supported by licensing routine |
Contact DataKinetics Technical Support for assistance. |
DK100823W |
DK1TLICK not authorized to enter key 0 |
Contact DataKinetics Technical Support for assistance. |
DK100824W |
PC Server <vvvv> not found |
Ensure that the PC Server for this release is running. |
DK100825W |
Licensing subroutine returned RC=<rrrrr> |
Contact DataKinetics Technical Support for assistance. |
DK100826W |
<pppppppp> license expired <yyyy-mm-dd>; in grace period |
The license for the named product has expired and it is now running in the grace period. It will stop functioning after the grace period. |
DK100827W |
<pppppppp> license expired <yyyy-mm-dd> |
The license for the named product has expired and the product has stopped functioning. |
DK100828W |
<pppppppp> license will expire <yyyy-mm-dd> |
The named product is in the warning period for its license and will no longer be licensed on the specified date. |
DK100829W |
<pppppppp> license expires today <yyyy-mm-dd> |
Just after midnight today, the named product will no longer be licensed. If there is a grace period, the product will continue to function during that period. |
DK100830W |
<pppppppp> license module DK1xBASE missing |
The license module specified for the named product is missing. |
DK100831W |
<pppppppp> DK1xBASE <vvvv> mismatch <vvvv> |
The license module specified for the named product is for a different version. |
DK100832W |
<pppppppp> DK1xBASE return code <rrrr> |
Contact DataKinetics Technical Support for assistance. |
DK100833I |
<pppppppp> licensed to <customer> |
Information only. |
DK100844S |
Customer Anchor Table DKL slot invalid: RC=<r>. |
Contact DataKinetics Technical Support for assistance. |
DK100847S |
cannot start, too many DKL products |
Contact DataKinetics Technical Support for assistance. |
DK100848S |
TPM may be running, run DK1PTERM |
Applicable only for VTS Manager. |
DK100849S |
Replacing corrupted GCA |
Contact DataKinetics Technical Support for assistance. |
DK100850I |
deleting NT |
Information only. |
DK100851I |
NT deleted |
Information only. |
DK100852I |
freeing PC code |
Information only. |
DK100853I |
PC code freed |
Information only. |
DK100854I |
Freeing GCA |
Information only. |
DK100855I |
Freeing GCAX |
Information only. |
DK100856I |
GCA purged |
Information only. |
DK100857I |
Replacing corrupted Dummy TPM block |
Information only. |
DK100858S |
PC Server unable to obtain storage |
Contact DataKinetics Technical Support for assistance. |
DK100859I |
Completing Dummy TPM/TPV blocks |
Information only. |
DK100870W |
LXFRE Bad Return Code |
Contact DataKinetics Technical Support for assistance. |
DK100871S |
$DOPC GETMAIN Failed |
Contact DataKinetics Technical Support for assistance. |
DK100872E |
LXFREE Getmain Failed |
Contact DataKinetics Technical Support for assistance. |
DK100873W |
LXFREE Freemain Failed |
Contact DataKinetics Technical Support for assistance. |
DK100874S |
$DOPC SCHEDIRB Macro Failed |
Contact DataKinetics Technical Support for assistance. |
DK100875S |
$DOPC DK1TPC11 Routine Failed |
Contact DataKinetics Technical Support for assistance. |
DK100876S |
$DOPC LOADROTB Service Failed |
Contact DataKinetics Technical Support for assistance. |
DK100877I |
DK1TVROT Named Token Failed |
Information only. |
DK100900S |
Not licensed for VTS Manager options |
Your installation is not licensed for this feature. Contact DataKinetics Technical Support for further information. |
DK100901S |
Not licensed for VTS Gate options |
Your installation is not licensed for this feature. Contact DataKinetics Technical Support for further information. |
DK100902S |
Not licensed for DEFAULT_TSR options |
Your installation is not licensed for this feature. Contact DataKinetics Technical Support for further information. |
DK100990S |
Incompatible ROOT and NUCLEUS versions |
Contact DataKinetics Technical Support for assistance. |
DK100991E |
Parms module not loaded |
Contact DataKinetics Technical Support for assistance. |
DK100993E |
Parms module corrupted |
Contact DataKinetics Technical Support for assistance. |