DataKinetics recommends adding all of the module names to your MPR pre-load members. Not all of the modules included in Table 24 are needed in certain IMS MPR configurations. However, determining which modules are required depends on many factors, including whether your applications call tableBASE dynamically or statically and whether or not your application load modules have been re-linked with the tableBASE Version 6 stub. The larger modules reside above the line, many others are aliases of DK1TCALL. It is simplest to load all of the names in your MPR pre-load.
Pre-Load Module |
Alias of |
Size (approx) Bytes |
Above line |
---|---|---|---|
70000 |
Yes |
||
DK1TNUCL2 |
100000 |
Yes |
|
DK1IBASE |
2000 |
Yes |
|
DK1TVROT |
10 |
Yes |
|
DK1TNTPD |
16 |
Yes |
|
DK1TNAME |
1300 |
Yes |
|
DK1TCALL |
6000 |
No |
|
TBCALLI |
DK1TCALL |
No |
|
TBROOTI |
DK1TCALL |
No |
|
TBASEV |
DK1TCALL |
No |
|
TBCALLV |
DK1TCALL |
No |